CAD DRAWINGS AND SCHEMATICS

Drawing register and viewer

Every drawing set of this project by revision — the current PROPOSED revision first, earlier revisions and superseded sets kept. Native verification, proposal status and professional checking are shown separately.

P07 PROPOSED — not accepted, not engineer approved, not for construction

Checked by / approved by: NOT RECORDED — no verified engineer identity; nothing here is engineer approved or issued for construction.

20 sheets at P07 — the current PROPOSED revision (not accepted, not engineer approved, not for construction)

WF1-HXA-ZZ-GF-DR-M-5011

Ventilation GA — ground floor part plan 1 (west)

Revision P07 · NATIVE EXECUTED — not accepted (see the native review)

native Revit sheet (APS Revit 2026 work item) — set native-revit-ga-v10-sheets (wf1-NATIVE-REVIT-APS-GA-20261021-fc372ee3-SHEETS)

100%
PDFDWG (native Revit export): local only
Native Revit GA
PASS NATIVE REVIT GA: PASS — native sheet checks 6 / 6, visual review PASS (run PASS 117 / 117, work item d8a57d57)
  • room outlines (synthetic case, halftone) and native Space names in clear floor area; one-line duct sizes; view title; general notes with cross-references
  • background NOT HELD (no architect model): stated on the sheet
Native AutoCAD DWG
NOT APPLICABLE DWG exported by native Revit (not an AutoCAD conversion)
Checking
Checked / approved: NOT RECORDED — not engineer approved, not for construction.
WF1-HXA-ZZ-GF-DR-M-5011 Ventilation GA — ground floor part plan 1 (west) (P07)
Other versions of M-5011 at P07 (8)
  • PROPOSED — not accepted, not checked, not approved
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence
  • SUPERSEDED — kept as evidence

Per-sheet files of work item d8a57d57 (run fc372ee3): DWGs byte-identical to the native exports, one unchanged page of the native PDF each, previews from a zero-origin copy. Sheet verdicts (native checks + visual review against the reference conventions): PASS 8, PARTIAL 2 (M-5302 D-D leader through a size label; M-5402 A-A size mark partly under a terminal symbol), FAIL 0. Room outlines = synthetic case geometry; room names = native Spaces. PROPOSED; not engineer reviewed.

Every set is read from its evidence folder or the project database and checked against its SHA-256; nothing is rewritten. Native AutoCAD DWGs are attached only by an acceptance record whose source SHA-256 equals the sheet's DXF. Native Revit GA status, proposal status and professional checking are separate.