ENGINEERING CRITERIA

Design criteria and parameters

Editable design parameters with their source classification. Every change needs a reason, shows its impact through the design chain and the BSRIA BG 6 deliverables, and is saved as a new revision.

Site, weather and standards

Current revision 3. 0 unsaved change(s).

Design conditions
SYNTHETIC (XX-TEST template)affects all native loads
SYNTHETIC (XX-TEST template)affects all native loads
SYNTHETIC (XX-TEST template)affects all native loads
SYNTHETIC (XX-TEST template)affects all native loads
Internal gains
SYNTHETIC (XX-TEST template)affects all native loads
SYNTHETIC (XX-TEST template)affects all native loads
Ventilation
SYNTHETIC (XX-TEST template)
SYNTHETIC (XX-TEST template)
Water temperatures
UNSTATED
UNSTATED
Air systems
SCENARIO
Sizing limits
SCENARIO
SCENARIO
SCENARIO
SCENARIO
Plant selection
ENGINEER SELECTION — the values below are defaults until an engineer selects (criteria edit)
ENGINEER SELECTION — the values below are defaults until an engineer selects (criteria edit)
ENGINEER SELECTION — the values below are defaults until an engineer selects (criteria edit)
ENGINEER SELECTION — the values below are defaults until an engineer selects (criteria edit)
Room r01a — Open-plan office zone 1
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r01b — Open-plan office zone 2
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r01c — Open-plan office zone 3
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r01d — Open-plan office zone 4
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r02 — Meeting room 1
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r03 — Meeting room 2
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r04 — Reception
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r05 — WC female
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r06 — WC male
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r07 — Accessible WC
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r08 — East lift lobby
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
Room r09 — Mechanical plantroom
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads
SYNTHETIC (XX-TEST template)affects room loads

Revision history

  1. Revision 3 20 Oct 2026, 06:50 · human:dev-unverified:XX-TEST operator (review replay) — Native IESVE loads applied from wf1-NATIVE-IESVE-RUN4-20261019-r3
    • Room r01a — Open-plan office zone 1: Occupancy 17 → 34 person
    • Room r01a — Open-plan office zone 1: Lighting 8 → 16 W/m²
    • Room r01b — Open-plan office zone 2: Occupancy 17 → 34 person
    • Room r01b — Open-plan office zone 2: Lighting 8 → 16 W/m²
    • Room r01c — Open-plan office zone 3: Occupancy 17 → 34 person
    • Room r01c — Open-plan office zone 3: Lighting 8 → 16 W/m²
    • Room r02 — Meeting room 1: Occupancy 12 → 24 person
    • Room r02 — Meeting room 1: Lighting 8 → 16 W/m²
    • Room r03 — Meeting room 2: Occupancy 12 → 24 person
    • Room r03 — Meeting room 2: Lighting 8 → 16 W/m²
  2. Revision 2 20 Oct 2026, 06:50 · human:dev-unverified:XX-TEST operator (review replay) — R04 (WF1 Run 4 owner change: occupancy x2 and lighting x2 in MT000000, MT000001, PN000000, PN000001, PN000002); raised by XX-TEST designer; owner-confirmed 2026-10-19: the Run 4 change is DOUBLE the original occupancy and DOUBLE the original lighting gains (x2, i.e. a 100% increase), NOT a 200% increase.
    • Room r01a — Open-plan office zone 1: Occupancy 17 → 34 person
    • Room r01a — Open-plan office zone 1: Lighting 8 → 16 W/m²
    • Room r01b — Open-plan office zone 2: Occupancy 17 → 34 person
    • Room r01b — Open-plan office zone 2: Lighting 8 → 16 W/m²
    • Room r01c — Open-plan office zone 3: Occupancy 17 → 34 person
    • Room r01c — Open-plan office zone 3: Lighting 8 → 16 W/m²
    • Room r02 — Meeting room 1: Occupancy 12 → 24 person
    • Room r02 — Meeting room 1: Lighting 8 → 16 W/m²
    • Room r03 — Meeting room 2: Occupancy 12 → 24 person
    • Room r03 — Meeting room 2: Lighting 8 → 16 W/m²

    Native loads stale for r01a, r01b, r01c, r02, r03.

  3. Revision 1 20 Oct 2026, 06:50 · human:dev-unverified:XX-TEST operator (review replay) — Workflow 1 room template wf1-london-office-synthetic-01 and design basis adopted (template revision R02: WF1 room template + design basis aligned to the native IESVE Rev02 loads model; PROPOSED (recorded design-basis change; not engineer approved))