CALCULATIONS AND SCHEDULES

Calculations, schedules and BOQ

The current calculation package, equipment Required / Offered schedules and BOQ, with each run's own calculation workbook and schedules — by topic, with revision, source, native evidence status, previews and downloads.

P07 PROPOSED — not checked or approved by an engineer, not for construction

Checked by / approved by: NOT RECORDED — no verified engineer identity; nothing here is engineer approved or issued for construction.

PROPOSED — not checked or approved by an engineer, not for construction. Workbooks holding licensed CIBSE Guide C data stay local (named, with the reason); their review pages and every other workbook download here with their SHA-256.

Showing the documents for CHWP-01A/B — its data sheet "M30 CHWP-01A-B" is open below.

Hydraulic and fitting losses, index runs

Pump and fan index runs and duties (lower bounds until manufacturer data is held)

Index runs and duties (Run 4, plan r11-r7) — PROVISIONAL - not engineer reviewed; duties are lower bounds unless stated
Pump / fanSystemFlowGoverning endIndex pressureStatusMissing
CHWP-01A/BHW-CHW3.935979 l/sFCU-GF-0982.8 kPaPARTIAL (lower bound)fittings: Guide C outside its stated range (34 cases, flagged); coil water Δp (FCU-GF-09); strainer (FCU-GF-09); isolation valves / flow measurement (FCU-GF-09); plant side (heat pump / chiller, headers, strainers) (CHWP-01A/B)
LTHWP-01A/BHW-LTHW1.367981 l/sFCU-GF-0940.2 kPaPARTIAL (lower bound)fittings: Guide C outside its stated range (22 cases, flagged); coil water Δp (FCU-GF-09); strainer (FCU-GF-09); isolation valves / flow measurement (FCU-GF-09); plant side (heat pump / chiller, headers, strainers) (LTHWP-01A/B)
AHU-01 supply fanOA1933.4 l/sFCU-GF-1083.4 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (29 cases, flagged); terminal (grille / FCU spigot) Δp (FCU-GF-10); unit internal + louvres / attenuators (AHU-01)
AHU-01 extract fanGEX1621.4 l/sEG-GF-06128.2 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (20 cases, flagged); terminal (grille / FCU spigot) Δp (EG-GF-06); unit internal + louvres / attenuators (AHU-01)
EF-01WCX312 l/sXG-GF-0525.1 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (12 cases, flagged); terminal (grille / FCU spigot) Δp (XG-GF-05); unit internal + louvres / attenuators (EF-01)

Lower bounds until the missing items are held; licensed CIBSE Guide C fitting coefficients stay local and are not shown. Source wf1-MECH-SCHEDULES-20261020-r11-r7-r5/pressure-losses.json (SHA-256 eb1cf9451a57).

Calculation package (P07)

PROPOSED — not accepted, not checked, not approvedP07Run 4

Source: wf1-STAGE4-WORKBOOKS-FINAL-20261021-r2 (manifest SHA-256 08ce9ab12163)

  • HEXANTA_WF1_RUN4_Calculation_Package_LOCAL_ONLY.xlsx — local only: listed in the manifest but not present on this host SHA-256 944b2f121565
  • Download PDF HEXANTA_WF1_RUN4_Calculation_Package_REVIEW_PAGES.pdf · SHA-256 6439892b0dc7

Calculation workbook — Run 4

Change run — criteria revision 3 — RECORDED (verified evidence, not re-run)criteria revision 3Run 4

Source: run output workbook/HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx

  • Download XLSX HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx · SHA-256 3673258e2c71

Calculation workbook — Run 3

Baseline run — criteria revision 1 — RECORDED (verified evidence, not re-run)criteria revision 1Run 3

Source: run output workbook/HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx

  • Download XLSX HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx · SHA-256 4d2d80a18d28

Preview

Equipment data sheets — Appendix A (Required / Offered, P07) — HEXANTA_WF1_RUN4_Equipment_Data_Sheets_Appendix_A.xlsx

Loading preview…