CALCULATIONS AND SCHEDULES

Calculations, schedules and BOQ

The current calculation package, equipment Required / Offered schedules and BOQ, with each run's own calculation workbook and schedules — by topic, with revision, source, native evidence status, previews and downloads.

P07 PROPOSED — not checked or approved by an engineer, not for construction

Checked by / approved by: NOT RECORDED — no verified engineer identity; nothing here is engineer approved or issued for construction.

PROPOSED — not checked or approved by an engineer, not for construction. Workbooks holding licensed CIBSE Guide C data stay local (named, with the reason); their review pages and every other workbook download here with their SHA-256.

Showing the documents for AHU-01 extract fan — no data sheet of this tag is held.

Hydraulic and fitting losses, index runs

Pump and fan index runs and duties (lower bounds until manufacturer data is held)

Index runs and duties (Run 4, plan r11-r7) — PROVISIONAL - not engineer reviewed; duties are lower bounds unless stated
Pump / fanSystemFlowGoverning endIndex pressureStatusMissing
CHWP-01A/BHW-CHW3.935979 l/sFCU-GF-0982.8 kPaPARTIAL (lower bound)fittings: Guide C outside its stated range (34 cases, flagged); coil water Δp (FCU-GF-09); strainer (FCU-GF-09); isolation valves / flow measurement (FCU-GF-09); plant side (heat pump / chiller, headers, strainers) (CHWP-01A/B)
LTHWP-01A/BHW-LTHW1.367981 l/sFCU-GF-0940.2 kPaPARTIAL (lower bound)fittings: Guide C outside its stated range (22 cases, flagged); coil water Δp (FCU-GF-09); strainer (FCU-GF-09); isolation valves / flow measurement (FCU-GF-09); plant side (heat pump / chiller, headers, strainers) (LTHWP-01A/B)
AHU-01 supply fanOA1933.4 l/sFCU-GF-1083.4 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (29 cases, flagged); terminal (grille / FCU spigot) Δp (FCU-GF-10); unit internal + louvres / attenuators (AHU-01)
AHU-01 extract fanGEX1621.4 l/sEG-GF-06128.2 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (20 cases, flagged); terminal (grille / FCU spigot) Δp (EG-GF-06); unit internal + louvres / attenuators (AHU-01)
EF-01WCX312 l/sXG-GF-0525.1 PaPARTIAL (lower bound)fittings: Guide C outside its stated range (12 cases, flagged); terminal (grille / FCU spigot) Δp (XG-GF-05); unit internal + louvres / attenuators (EF-01)

Lower bounds until the missing items are held; licensed CIBSE Guide C fitting coefficients stay local and are not shown. Source wf1-MECH-SCHEDULES-20261020-r11-r7-r5/pressure-losses.json (SHA-256 eb1cf9451a57).

Calculation package (P07)

PROPOSED — not accepted, not checked, not approvedP07Run 4

Source: wf1-STAGE4-WORKBOOKS-FINAL-20261021-r2 (manifest SHA-256 08ce9ab12163)

  • HEXANTA_WF1_RUN4_Calculation_Package_LOCAL_ONLY.xlsx — local only: listed in the manifest but not present on this host SHA-256 944b2f121565
  • Download PDF HEXANTA_WF1_RUN4_Calculation_Package_REVIEW_PAGES.pdf · SHA-256 6439892b0dc7

Calculation workbook — Run 4

Change run — criteria revision 3 — RECORDED (verified evidence, not re-run)criteria revision 3Run 4

Source: run output workbook/HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx

  • Download XLSX HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx · SHA-256 3673258e2c71

Calculation workbook — Run 3

Baseline run — criteria revision 1 — RECORDED (verified evidence, not re-run)criteria revision 1Run 3

Source: run output workbook/HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx

  • Download XLSX HEXANTA_WF1_MECHANICAL_DESIGN_CALCULATIONS.xlsx · SHA-256 4d2d80a18d28

Preview

Choose “Preview sheets”, a sheet or “Preview PDF” above.